Compute Comparison
vs
All comparisons →

Blackwell Ultra

NVIDIA GB300 NVL72

wins

4

The GB300 NVL72 is NVIDIA's Blackwell Ultra rack-scale system — 72 GPUs in a single rack delivering 7,500 TFLOPS FP16 per GPU.

Next-gen frontier trainingTrillion-param inferenceRack-scale AI

Hopper

NVIDIA H100 SXM5 80GB

wins

1

The H100 SXM5 is the high-performance form factor of the H100.

LLM trainingMulti-GPU NVLink clustersHigh-throughput inference

Performance comparison

Visual bars — winner highlighted

NVIDIA GB300 NVL72

Metric

NVIDIA H100 SXM5 80GB

FP16 Tensor TFLOPS (dense)

7.5k T
989 T

Bandwidth

16.0k GB/s
3.4k GB/s

VRAM

288 GB
80 GB

TDP (lower=better)

1.2k W
700 W

TFLOPS/watt

6.25
1.41

GB/s per watt

13.33
4.79

Full specification table

SpecNVIDIA GB300 NVL72NVIDIA H100 SXM5 80GB
ArchitectureBlackwell UltraHopper
VRAM288 GB HBM3e (per GPU)80 GB HBM3
VRAM typeHBM3e (per GPU)HBM3
Memory bandwidth16,000 GB/s3,350 GB/s
FP16 Tensor TFLOPS (dense)7,500 TFLOPS989 TFLOPS
TDP1,200 W700 W
TFLOPS/watt6.25 T/W1.41 T/W
GB/s per watt13.33 GB/s/W4.79 GB/s/W
NVLinkYesYes
Release year20262022

Live cloud pricing

On-demand pricing across providers — updated in real time

Per hourPer GB VRAM/hr
Loading prices…

Power efficiency analysis

TFLOPS/watt and GB/s/watt — critical for data center TCO

NVIDIA GB300 NVL72

FP16 TFLOPS7,500 TFLOPS
TDP1,200 W
TFLOPS/watt6.250 T/W
GB/s per watt13.33 GB/s/W

NVIDIA H100 SXM5 80GB

FP16 TFLOPS989 TFLOPS
TDP700 W
TFLOPS/watt1.413 T/W
GB/s per watt4.79 GB/s/W

TFLOPS/watt measures compute efficiency — how much AI throughput you get per watt of power consumed. For data centers with PUE of 1.2–1.5, a 10% improvement in TFLOPS/watt translates directly to lower electricity costs and cooling requirements. GB/s/watt measures memory bandwidth efficiency, which is the binding constraint for memory-bound LLM inference workloads.

When to choose each GPU

Choose NVIDIA GB300 NVL72 for:

  • Next-gen frontier training
  • Trillion-param inference
  • Rack-scale AI

Weaknesses / Limitations

  • Rack-scale system — not a single GPU, requires full NVL72 rack deployment
  • Extremely high cost — rack-scale pricing only
  • Very limited availability, primarily hyperscaler deployments

Choose NVIDIA H100 SXM5 80GB for:

  • LLM training
  • Multi-GPU NVLink clusters
  • High-throughput inference

Weaknesses / Limitations

  • Highest cost per H100 variant — premium over PCIe form factor
  • SXM5 form factor requires NVLink-capable server chassis
  • 700W TDP demands high-density power and cooling infrastructure